8–21

Error Codes

Reverse Print Errors

111

REVERSE format error in input parameters

Re–enter the command with proper format.

112

REVERSE starting row SR/ending row ER out of bounds

Exceeds the value specified to reverse the element.

113

REVERSE starting SC/ending column EC out of bounds

Exceeds the value specified to reverse the element.

114

Insufficient memory to store the REVERSE element

Insufficient memory space available for reversed print requirements.

115–116 Not defined.

117

Unusable or illegal raster data.

118

Unsupported raster image type.

119

Unsupported raster compression type.

120–125 Not defined.

126

LFORMx form length parameter n error

The number of lines exceeds 66 (for 6 lpi) or 88 (for 8 lpi) lines when using

the LFORMx command.

127

Form length > physical page length

The form length specified exceeds the paper size loaded in the printer.

128

FORM/LOGO name is not a legal file name

The file name exceeds the twelve-character limitation, or an invalid character

was used in the file name. Refer to IGP/PGL Command Standards in the

“Commands” chapter.

129

Not defined.