Printronix ThermaLine Series User Manual

Page 203

Advertising
background image

5–65

Bar Codes

Quiet Zone

Quiet zones extend on both ends of the bar code to permit the scan to begin

and end in a blank area. The IGP/PGL automatically produces an 11-

module-wide left quiet zone; you are responsible for providing sufficient

space (minimum of seven modules) on the form for the right quiet zone.

The number system character is also printed automatically in the left quiet

zone.

Start/Center/Stop Codes

The start/center/stop codes are special character codes marking those

portions of the bar code. These codes are automatically provided.

Number System Character

The number system character field allows you to provide a code to a class

or type of item. The first character in the data field is used as the number

system character.

Data Field

The bar code symbol uses a series of varying width bars and spaces to

represent a limited character set (numbers 0–9 and Special Characters Start,

Center, and Stop). The bars and spaces vary in width from one to four

modules. Each character consists of two bars and two spaces that total

seven modules. The symbol coding of the left data field is different from

the right data field to permit read direction sensing.

The optional 2– or 5–digit add–on data field is placed within the delimiter

at the end of the bar code data and typically identifies a periodical issue

number or price, respectively.

Readable Data

The human readable data field provides a readable interpretation of the bar

code data. It can either be suppressed or printed below the bar code symbol.

Check Digit

The modulo–10 check digit is automatically calculated and inserted in the

bar code symbol. The check digit verifies accurate scanning. The number

system character is included in the check digit algorithm.

Advertising