Bar Codes

5–112

Quiet Zone

Quiet zones extend on both ends of the bar code to permit the scan to begin

and end in a blank area. The IGP/PGL automatically produces an

11–module wide left quiet zone. You must provide sufficient space

(minimum of seven modules) on the form for the right quiet zone. The

number system character is also printed automatically in the left quiet zone.

Start/Stop Codes

The start/stop codes are special character codes marking those portions of

the bar code. These codes are automatically provided.

Number System Character

The number system character field for all UPC–E and UPC–E0 bar codes

must be zero.

Data Field

The bar code symbol uses a series of varying width bars and spaces to

represent a limited character set (numbers 0–9 and Special Characters Start

and Stop). The bars and spaces vary in width from one to four modules.

Each character consists of two bars and two spaces that total seven

modules.

For UPC–E, eleven digits are expected, which are compressed down to the

six encoded symbol characters. For UPC–E0, six compressed digits are

expected.

The optional 2– or 5–digit add–on data field is placed at the end of the bar

code and typically identifies a periodical issue number or price,

respectively.

Readable Data

The human readable data field provides a readable interpretation of the bar

code data. It can either be suppressed or printed above or below the bar

code symbol.

Check Digit

The modulo–10 check digit is automatically calculated and inserted in the

bar code symbol. The check digit verifies accurate scanning. The number

system character is included in the check digit algorithm.