Error Codes

8–18

Bar Code Errors

90

Insufficient memory to store the BARCODE

No more room exists in the IGP/PGL memory for another bar code. The rest

of the bar code commands are flushed until the Stop command is found.

Processing will then continue.

91

ALPHA/BARCODE syntax error

Some type of syntax (format) error was detected in the parameters of the bar

code command. This error is usually caused by one or more of the following:

a. Misspelled

keywords;

b. Lowercase

used;

c. A missing semicolon;

d. A colon in place of a semicolon;

e. An ending delimiter for the data field was not found;

f. Too many or too few parameters in the command string.

The rest of the command line is flushed until the Stop command is found.

Processing will then continue.

92

BARCODE magnification factor MAG out of bounds

The magnification factor specified in the bar code command is out of

bounds. Refer to the applicable section in the “Bar Codes” chapter to

determine the acceptable magnification values for the bar code symbol being

used.

93

BARCODE starting row SR out of bounds

The starting row parameter in the bar code command will cause the bar code

symbol to print either above or below the limits of the form.

94

BARCODE starting column SC out of bounds

The starting column parameter in the bar code command will cause the bar

code symbol to print either beyond the left margin or the right margin of the

form.

95

BARCODE height Hn out of bounds – must be 4 through 99

The height parameter specified in the bar code command is out of bounds.

Acceptable values are 4 through 99.

96

BARCODE data field has illegal character/format

A character in the data field was not recognized as an acceptable character.

Refer to the applicable section in the “Bar Codes” chapter to determine the