Commands
4–24
Comments
The Incremental Alphanumeric Fixed Data Fields command is a revised
version of the standard IGP/PGL alphanumeric command, but it does not
replace the standard alphanumeric command.
~CREATE;TEST;288
(Enters Create Form mode)
VDUP;3;6
(Repeat alpha string)
ALPHA
(Alpha command)
I;6;5;4;4;–00001;*12345*
STOP
(Ends Alpha command)
VDUP;OFF
END
(Terminates Create Form mode)
~EXECUTE;TEST
(Prints form)
~NORMAL