Bar Codes

SR

Defines the starting row for the bar code. Enter a value

ranging from row 1 to one less than the length of the

form. Character row or dot row is specified based on

the Scale command (page 4–88), or use the CP.DP

format (page 4–7).

SC

Defines the starting column of the bar code. Enter a

value ranging from column 1 to one less than the width

of the form. Character column or dot column is

specified based on the Scale command (page 4–88), or

use the CP.DP format (page 4–7).

D

The printable character (delimiter) identifying the start

and finish of the data field. Enter any printable

character other than a slash (/), the SFCC, or a

character used within the data. The same character

must be used at both ends of the data field, but it will

not print with the data.

data field

The characters of the bar code data are restricted to

exactly seven digits. If the 2– or 5–digit add–on data

option is used, include this data at the end of the data

field. The characters available for the data field are 0

through 9 (30 through 39 hex, respectively).

PDF

Optional parameter to print the human readable data

field. The data field prints automatically unless the

PDF–suppress command is specified in the FONT

parameter. The human-readable data field can be

printed above or below the bar code symbol.

This parameter is not allowed if a null data field is

specified. If no PDF command is entered, the data

field will print automatically in the default OCR–B

font.

LOC

Optional parameter to identify the location of the

printable data field. The default value is B, locating the

human readable data below the bar code. A locates the

printable data field above bar code. To compensate for

printing the 0.1–inch high data, the height of the bar

code body is reduced 0.1 inch.