Printronix ThermaLine Series User Manual

Page 259

Advertising
background image

5–121

Bar Codes

Incrementing Bar Code Data

The IGP/PGL internally counts incremental static (fixed) bar code data

fields. A maximum of 255 incremental fixed bar code data fields are allowed

per form.

Incrementing is controlled with the STEPMASK and STARTDATA

command parameters as described in Table 5–18. The parameters are part of

the bar code command or part of the Execute command when using the

Incremental Bar Code Dynamic Data command.

The STEPMASK parameter performs three functions:

1.

It defines the increment amount (step);

2.

It defines the number of characters allowed in the data field

(STARTDATA); and

3.

It provides a “mask” to link or unlink subfields of data for individual

incremental activity. The data provided in the STEPMASK field

combined with the data in the STARTDATA field determine the result of

these functions.

Table 5–18. Incremental Bar Code Data

0 – 9

0 – 9

0 – 9

A – Z

0 – 9

Space

0 – 9

Not A – Z

or 0 – 9

Error

Not 0 – 9

or L

Any

L

Any

Alpha characters are incremented by amount in
STEPMASK field.

Numeric characters are incremented by amount in
STEPMASK field.

Same character type as character in the next right ad-
jacent, linked increment position. Character type is
numeric if in the least significant position.

Non–incrementing alphanumeric character

Linked, non–incrementing alphanumeric character

STEPMASK

STARTDATA

Character Type and Function

Advertising