background image

Bar Codes

5–108

SR

Defines the starting row for the bar code. Enter a value

ranging from row 1 to one less than the length of the

form. Character row or dot row is specified based on

the Scale command (page 4–88), or use the CP.DP

format (page 4–7).

SC

Defines the starting column of the bar code. Enter a

value ranging from column 1 to one less than the width

of the form. Character column or dot column is

specified based on the Scale command (page 4–88), or

use the CP.DP format (page 4–7).

D

The printable character (delimiter) identifying the start

and finish of the data field. Enter any printable

character other than a slash (/), the SFCC, or a

character used within the data. (It will not print with

the data.) Use the same character at both ends of the

data field.

data field

Enter the characters for the bar code data, restricted to

exactly 11 digits. If the 2– or 5–digit add–on data

option is used, include this data at the end of the data

field. The first digit is interpreted as the number system

character. The remaining 10 digits are the data field

characters. The characters available for the data field

are 0 through 9 (30 through 39 hex, respectively).

PDF

Optional parameter which affects printing of the

human readable data field. The data field will print

automatically unless the PDF–suppress command is

specified in the FONT parameter. OCR-B characters

can be printed above or below the bar code symbol.

This parameter is not allowed if a null data field is

specified. If the PDF command is not entered in the

UPC–A command format, the data field automatically

prints in OCR–B.

Advertising