Chapter 5: Management with WebPAM PRO

171

2.

Click the Disk Arrays

icon.

3.

Click the Disk Array icon.

4.

Click the Logical Drives icon

5.

Click the Logical Drive icon.

6.

Click the Check Table tab in Management View.

7.

Click the option for the table you want to see.
The default is All tables.
If there are entries, they are listed as follows:

Entry Number

– A number assigned to each block of entry.

Table Type

– Read Check, Write Check or Inconsistent Block (see

below).

Start Logical Block Address

– LBA of the first block for this entry.

Count

– Number of continuous blocks starting from this LBA.

Read Check Table

– Contains a list of read errors for this logical drive.

Write Check Table

– Contains a list of write errors for this logical drive.

Inconsistent Block Table

– Contains a list of inconsistent blocks for

this logical drive.

Mirror data for RAID Levels 1, 1E, and 10.

Parity data for RAID Levels 5, 6, 50, and 60.

Inconsistent blocks are identified by the Redundancy Check.