Finding the failed drive in webpam pro – Promise Technology Network Device EX8654 User Manual

Page 278

Advertising
background image

SuperTrak EX Series User Manual

264

Figure 3. Physical Drive Management screen

In the example above, there is no physical drive for ID 3. Assuming you
installed a physical drive onto Channel 3 of the SuperTrak controller, this is
the failed physical drive.

3.

Shut down the Host PC, open the case, check the power and data
connections to each physical drive, correct any shortcomings, restart the
Host PC and check in SuperBuild again.

Finding the Failed Drive in WebPAM PRO

To locate a failed or missing physical drive:
1.

Open WebPAM PRO.
See “Logging into WebPAM PRO” on
page 107 fo
r more information.

2.

Click the Subsystem

icon in Tree View.

3.

Click the Enclosures icon.

4.

Click the Enclosure icon.

5.

Click the Physical Drives icon.

6.

Examine the list of physical drives.

If a drive was present but is now
missing, that is the failed drive. Check
the power and data connections. If
those are OK, you must replace the
drive.

If a drive is marked as PFA or Stale,
that is the problem drive and you might
be able to salvage the drive.

If a drive is marked as Offline or Dead,
that is the problem drive and you must replace it.

ID 3 is missing