Scenario 3: external enclosures - daisy chain, Scenario 4: external enclosures - parallel, Scenario 5: sas expanders – Promise Technology Network Device EX8654 User Manual

Page 30

Advertising
background image

SuperTrak EX Series User Manual

16

In WebPAM PRO, the Host PC appears as Enclosure 1. The drives on Port
Ch1-4 are numbered 1 to 4. The drives on Port Ch5-8 are numbered 129 to 132.

This scenario also applies if you use Promise SuperSwap enclosures.

Scenario 3: External Enclosures – Daisy Chain

You install the SuperTrak card into a Host PC. You attach a SAS data cable
between Port Ch1-4 and a Promise VTrak J310s 12-drive JBOD enclosure. You
connect a second J310s enclosure to the first in a daisy chain.

In WebPAM PRO, the first JBOD enclosure appears as Enclosure 2. The drives
are numbered 1 to 12. The second JBOD enclosure appears as Enclosure 3. The
drives are numbered 13 to 24.

Scenario 4: External Enclosures – Parallel

You install the SuperTrak card into a Host PC. You attach a SAS data cable
between Port Ch1-4 and a VTrak J310s enclosure. You attach a SAS data cable
between Port Ch5-8 and a second J310s enclosure.

In WebPAM PRO, the first JBOD enclosure appears as Enclosure 2. The drives
are numbered 1 to 12. The second JBOD enclosure appears as Enclosure 10.
The drives are numbered 129 to 140.

Scenario 5: SAS Expanders

You install the SuperTrak card into a Host PC. You attach a SAS data cables
between Ports Ch1-4 and Ch5-8 and two SAS Expanders.

In WebPAM PRO, the first Expander appears as Enclosure 2. The drives are
numbered 1 to 128. The second Expander appears as Enclosure 10. The drives
are numbered 129 to 256.

See “Viewing Enclosure Information” on page 145 and “Locating a Physical
Drive” on page 146
for more information.

Advertising