Connector signals, Push – Panasonic AJ-HPX2000 User Manual

Page 141

Advertising
background image

141

Maintenance and Inspections : Maintenance

M

a

in

te

nan

ce an

d Insp

ecti

on
s

‹

Note

Ensure that the polarities are used correctly for a power
supply from an external source.

Connector Signals

DC IN

1

GND

2

NC

3

NC

4

+12V

FRONT MIC IN

1

GND

2

L CH IN (H)

3

L CH IN (C)

4

R CH IN (H)

5

R CH IN (C)

AUDIO IN

1

GND

2

AUDIO IN(H)

3

AUDIO IN(C)

AUDIO OUT

1

GND

2

L CH OUT (H)

3

L CH OUT (C)

4

R CH OUT (H)

5

R CH OUT (C)

1

2

3

4

Matsushita part number K1AA104H0038
Maker part number

HA16RX-4P SW1
(Hirose Denki)

PUSH

1

5

2

3

4

Matsushita part number K1AB105B0002
Maker part number

NC5FBH
(NEUTRIK)

PUSH

1

3

2

Matsushita part number K1AB103A0011
Maker part number

HA16PRM-3SG
(Hirose Denki)

5

4

3

2

1

Matsushita part number K1AA105H0016
Maker part number

HA16RD-5P(76)
(Hirose Denki)

DC OUT

1

GND

2

R TALLY
(Open collector)

3

REC START SW

4

+12V OUT
(Max. 1.5 A)

1

2

3

4

Matsushita part number K1AY104J0001
Maker part number

HR10A-7R-4SC(73)
(Hirose Denki)

Connector at the cable side
Maker part number

HR10A-7R-4P(73)
(Hirose Denki)

AJ-HPX2000P(VQT1D27-1)E.book 141 ページ 2007年7月30日 月曜日 午後1時31分