Specifications

© National Instruments Corporation

A-9

DIO 6533 User Manual

Environment

Operating temperature ........................0 to 55

°

C

Storage temperature ............................–20 to 70

°

C

Relative humidity ...............................5% to 90% noncondensing

Functional shock .................................MIL-T-28800 E Class 3 (per

Section 4.5.5.4.1) Half-sine
shock pulse, 11 ms duration,
30 g peak, 30 shocks per face

Operational random vibration .............5 to 500 Hz, 0.31 grms, 3 axes

Nonoperational random vibration........5 to 500 Hz, 2.5 grms, 3 axes

Note:

Random vibration profiles were developed in accordance with
MIL-T-28800E and MIL-STD-810E Method 514. Test levels exceed those
recommended in MIL-STD-810E for Category 1 (Basic Transportation,
Figures 514.4-1 through 514.4-3).