Figure 526. burst mode output timing (default), Figures 5-26 – National Instruments DIO 6533 User Manual

Page 89

Advertising
background image

Chapter 5

Signal Timing

DIO 6533 User Manual

5-30

© National Instruments Corporation

Figure 5-26. Burst Mode Output Timing (Default)

Parameter

Description

Minimum

Maximum

Input Parameters

t

pc

PCLK cycle time

50

t

pw

PCLK high pulse duration

20

t

pl

PCLK low pulse duration

20

t

rs

Setup time from REQ valid to PCLK falling
edge

1

t

rh

Hold time from PCLK to REQ invalid

0

Output Parameters

t

pa

PCLK to ACK valid

22

t

ah

Hold time from PCLK to ACK invalid

3

t

pdo

PCLK to output data valid

28

t

doh

Hold time from PCLK to output data invalid

5

All timing values are in nanoseconds.

PCLK

ACK

Data Out

REQ

trs

tpa

tpdo

tpw

tpl

tpc

tdoh

trh

tah