Figure 521. trailingedge mode output, Trailing-edge mode timing specifications -25, Figure 5-21. trailing-edge mode output -25 – National Instruments DIO 6533 User Manual

Page 84: Trailing-edge mode timing specifications

Advertising
background image

Chapter 5

Signal Timing

© National Instruments Corporation

5-25

DIO 6533 User Manual

Figure 5-21 shows a write transfer in trailing edge mode.

Figure 5-21. Trailing-Edge Mode Output

Trailing-Edge Mode Timing Specifications

Figures 5-22

and

5-23

show the timing diagrams for trailing-edge

mode.

Wait

For

Data

Wait

For

REQ

Programmable

Delay

Programmable

Delay

Wait

For

REQ

When REQ
Unasserted

When 6533 Device

Has Data to Output,

Output Data*

Clear

ACK

When REQ

Asserted

Initial State

ACK Cleared

Send

ACK

* With REQ-edge latching enabled, the data written is

delayed until the next inactive-going REQ edge.