Figure 517. long-pulse mode output, Long-pulse mode timing specifications -20, Figure 5-17. long-pulse mode output -20 – National Instruments DIO 6533 User Manual

Page 79: Long-pulse mode timing specifications

Advertising
background image

Chapter 5

Signal Timing

DIO 6533 User Manual

5-20

© National Instruments Corporation

Figure 5-17. Long-Pulse Mode Output

Long-Pulse Mode Timing Specifications

Figures 5-18

and

5-19

show the timing diagrams for long-pulse mode.

Wait

For

Data

Wait

For

REQ

Programmable

Delay

Programmable

Delay

Wait

For

REQ

When REQ

Asserted

When 6533 Device

Has Data to Output,

Output Data*

Clear

ACK

Pulse

When REQ
Unasserted

Initial State

ACK Cleared

Send

ACK Pulse

* With REQ-edge latching enabled, the data written is

delayed until the next inactive-going REQ edge.

Advertising