Figure 522. trailingedge mode input timing, Figure 5-22. trailing-edge mode input timing -26, Figures 5-22 – National Instruments DIO 6533 User Manual

Page 85

Advertising
background image

Chapter 5

Signal Timing

DIO 6533 User Manual

5-26

© National Instruments Corporation

Figure 5-22. Trailing-Edge Mode Input Timing

Parameter

Description

Minimum

Maximum

Input Parameters

t

rr*

REQ pulse width

75

t

r*r

REQ inactive duration

75

t

dir*

Input data setup to REQ inactive
(with REQ-edge latching)

0

t

r*di

Input data hold from REQ inactive
(with REQ-edge latching)

10

t

dir

Input data setup to REQ
(with REQ-edge latching disabled)

0

t

adi

Input data hold from ACK
(with REQ-edge latching disabled)

0

Output Parameters

t

aa*

ACK pulse width

225

1

275

2

t

a*r*

ACK inactive to next REQ inactive

0

1

t

aa*

(min)

= 225 + programmable delay

All timing values are in nanoseconds.

2

t

aa*

(max) = 275 + programmable delay

REQ

ACK

Input Data

(REQ-edge latching)

Input Data

(REQ-edge

latching disabled)

tdir*

tr*r

tdir

taa*

ta*r*

trr*

tr*di

tadi

tadi