Figure 514. leadingedge mode input timing, Figure 5-14. leading-edge mode input timing -17, Figures 5-14 – National Instruments DIO 6533 User Manual

Page 76

Advertising
background image

Chapter 5

Signal Timing

© National Instruments Corporation

5-17

DIO 6533 User Manual

Figure 5-14. Leading-Edge Mode Input Timing

Parameter

Description

Minimum

Maximum

Input Parameters

t

rr*

REQ pulse width

75

t

r*r

REQ inactive duration

75

t

ar

ACK to next REQ

0

t

dir(1)

Input data setup to REQ active
(with REQ-edge latching)

0

t

rdi

Input data hold from REQ active
(with REQ-edge latching)

10

t

dir(2)

Input data setup to REQ
(with REQ-edge latching disabled)

0

t

adi

Input data hold from ACK
(with REQ-edge latching disabled)

0

Output Parameters

t

aa*

ACK pulse width

125

t

r*a*

REQ inactive to ACK inactive

150

All timing values are in nanoseconds.

REQ

ACK

Input Data

(REQ-edge

latching disabled)

tr*r

tr*a*

tdir(2)

tadi

tar

taa*

trr*

Input Data

(REQ-edge latching)

trdi

tdir(1)