Figure 4-4. Transmission Line Terminations

The following additional recommendations apply for all signal
connections to your 6533 device:

Separate 6533 device signal lines from high-current or high-voltage
lines. These lines are capable of inducing currents in or voltages on
the 6533 device signal lines if they run in parallel paths at a close
distance. To reduce the magnetic coupling between lines, separate
them by a reasonable distance if they run in parallel, or run the lines
at right angles to each other.

Do not run signal lines through conduits that also contain power
lines.

Protect signal lines from magnetic fields caused by electric motors,
welding equipment, breakers, or transformers by running them
through special metal conduits.