DIO 6533 User Manual

Absolute max input voltage range ....... –0.3 to 5 V

Power-on state for outputs ..................Tri-stated, pulled up or down

(selectable)

Data transfers ......................................Programmed I/O, DMA

Strobed I/O

Pattern Generation

Direction .............................................Input or output

Modes .................................................Internally or externally timed

Output low voltage

(I

OL

= 24 mA)

0.4 V

Output high voltage*

(I

OH

= 24 mA)

2.4 V