Chapter 4

Signal Connections

DIO 6533 User Manual

4-6

© National Instruments Corporation

Signal Characteristics

Following is a list of signal characteristics. Characteristics are for all
signals, unless otherwise noted. For signal characteristics not given in
this section, see Appendix A,

Specifications

.

• Drive current—After being enabled, all lines that can be configured

for output sink at least 24 mA at 0.4 V, and source at least 24 mA
at 2.4 V.

DAQCard-6533—Your PCMCIA socket may not provide
sufficient power to drive all outputs at 24 mA.

• Ground reference—All signals are referenced to the GND lines.

• Initial state—At power up, all control and data lines begin at high

impedance. With no load attached, the voltage levels of the lines
are controlled by the pull-up or pull-down resistors.

• Pull-up/pull-down

• Control lines—All timing control lines have 2.2 k

pull-up or

pull-down resistors, controlled by the CPULL line.

• Data lines—All timing data lines have 100 k

pull-up or

pull-down resistors, controlled by the DPULL line.

• Bias-selection lines—The CPULL and DPULL lines, which

select the bias of the control and data lines, are themselves
biased low with 20 k

pull-down resistors. The default bias of

all lines, therefore, is pulled down.

• Polarity

• Data signals—Active high. A 1 corresponds to a high voltage,

and a 0 corresponds to a low voltage.

• Control signals—Depending on the operating mode and

handshaking protocol you select, control signals can be active
high or active low.