Chapter 5 Checking the installation prerequisites

91

BCM200/400 4.0 Installation and Maintenance Guide

•

use of a station auxiliary power supply (SAPS) for loops 300 m (975 ft.) to 1200 m (3900 ft.).
In North America, the SAPS must be a CSA- or UL-approved Class 2 power source.
In Europe, the SAPS must be a Class II power source and CE marked.

•

no bridge taps

Analog loop

The following parameters must be met for an analog loop:

•

maximum DC loop resistance of 208

Ω

•

maximum cable length (0.5 mm or 24 AWG) of 1220 m (4000 ft.)

System equipment, supplies, and tools

Refer to the following sections for the equipment required to install the BCM system:

•

“Basic hardware”

•

“Optional equipment”

•

“Other hardware and tools” on page 92

Basic hardware

The BCM system consists of some combination of the following hardware:

•

main unit

•

expansion unit

•

media bay module (MBM)

•

telephones

•

cabling for connections between hardware units

Optional equipment

You can add the following equipment to the BCM system to support specific requirements beyond
the basic hardware:

•

station auxiliary power supply (SAPS)

•

key indicator module (KIM) for T7316E telephones

•

analog terminal adapter 2 (ATA2) if connecting analog equipment to a digital extension line

•

uninterruptable power supply (UPS)

•

analog emergency telephone

•

optional WAN card field replaceable unit (FRU)

Note: You must include specific features in the keycode file for some hardware to
function.