Chapter 3 Viewing the BCM system LEDs

83

BCM200/400 4.0 Installation and Maintenance Guide

Figure 48 DTM LEDs

Table 21

describes the functions of the DTM LEDs.

Table 21 DTM LED functions

LED Status

Descriptions

Power

–

Refer to

“Media bay module LEDs”

for details.

Status

–

Refer to

“Media bay module LEDs”

for details.

In service

Flashing

The T1, ETSI, or PRI trunks are out of service because a loopback test is
running or the DTM is initializing.

Loopback test

On

A continuity loopback test is running.

Receive alarm

On

A problem with the received digital transmission. This half-duplex link does
not work.

Receive error

On

A small error as a result of degraded digital transmission. Possible causes are
an ohmic connection, water ingress, or too long a loop.

Transmit alarm

On

The DTM cannot transmit. The DTM sends an alarm indication signal (AIS) to
the terminating switch. This half-duplex link does not work.

Transmit error

On

The DTM is sending a remote alarm indication (RAI) carrier failure alarm
(CFA) to the terminating switch. If the transmit alarm is not on, this error
indicates a far-end or cable problem.

All LEDs

Flashing

The DTM is initializing.

Tip: You can install a maximum of three DTM modules in the BCM main unit, depending
on the available buses.