4x16 switch settings, 4x16 – Nortel Networks BCM200/400 User Manual

Page 130

Advertising
background image

130

Chapter 8 Installing a media bay module (MBM)

N0060612

N0060612

4x16 switch settings

The 4x16 MBM combines a CTM and a DSM16. The CTM only requires four lines on the DS30
bus. Therefore, it can be assigned any of the four offsets in a DS30 bus. The DSM then
automatically assigns the next DS30 bus and all the assigned DNs.

The 4x16 MBM can be combined with three other CTMs or one CTM8 on the same DS30 bus.

Table 39

shows the switch settings for each DS30 bus, and the assigned lines and dialing numbers

(DNs) for each DS30 bus.

Table 39 4x16 switch settings

Select

DS30
bus #

Select

offset

Enter these switch settings

To assign

these lines

And this

DS30 bus

and DNs

2

Custom DN

range

1

2

3

4

5

6

02

0

on

on

on

on

on

on

211-214

DS30

bus 03

237-252

(2.5 upgrade)

253-268

(3.0 new)

1

on

on

on

on

on

219-222

off

2

on

on

on

on

on

227-230

off

3

on

on

on

on

235-238

off

off

03

0

on

on

on

on

on

181-184

DS30

bus 04

253-268

(2.5 upgrade)

285-292

(3.0 new)

off

1

on

on

on

on

189-192

off

off

2

on

on

on

on

197-200

off

off

3

on

on

on

205-208

off

off

off

04

0

on

on

on

on

on

151-154

DS30

bus 05

269-284

(2.5 upgrade)

317-332

(3.0 new)

off

1

on

on

on

on

159-162

off

off

2

on

on

on

on

167-170

off

off

3

on

on

on

175-178

off

off

off

05

0

on

on

on

on

121-124

DS30

bus 06

285-300

(2.5 upgrade)

349-364

(3.0 new)

off

off

1

on

on

on

129-132

off

off

off

2

on

on

on

137-140

off

off

off

3

on

on

145-148

off

off

off

off

Advertising