Removing an expansion unit fan, To remove an expansion unit fan – Nortel Networks BCM200/400 User Manual

Page 340

Advertising
background image

340

Chapter 25 Replacing or installing a cooling fan

N0060612

N0060612

7

Test the direction of the fan exhaust air flow to determine if the fan is correctly installed.

a

Hold a piece of paper or your hand close to the fan exhaust. A correctly installed fan blows
air away from the main unit.

b

If the fan exhaust air flow is incorrect, remove the cooling fan (see

“Removing a BCM200

cooling fan” on page 337

) and reinstall the fan in the correct orientation (this procedure).

Removing an expansion unit fan

The BCM expansion unit comes either with one fan or a redundant fan set. The single-fan unit is
not upgradeable.

To remove an expansion unit fan

1

Shut down the system (see

“Performing a system shutdown” on page 239

).

2

Disconnect the fan power cable from the hub card.

3

Locate the screws that fasten the fan casing to the expansion unit back wall and remove them.
Refer to

Figure 188 on page 341

and

Figure 189 on page 341

.

4

Remove the four screws (or snap rivets) that hold the fan to the expansion unit.

5

Lift the failed fan out of the expansion unit.

Warning: Protect the hardware components against damage from electrostatic discharge.
Always wear a grounded wrist strap before you handle components. Always place the
components in a static-free container.

Note: If the unit has redundant fans, each fan has a connector on the hub board.