Chapter 19 System monitoring and troubleshooting

233

BCM200/400 4.0 Installation and Maintenance Guide

To monitor RAID disk mirror operational status

1

Open Element Manager.

2

From the Administration tab, click System Status, and then click Disk Mirroring.

The Disk Mirroring screen displays.

3

Click on the Status tab

The Disk Mirroring screen displays the operational status of primary master and mirror master
disks.

4

Confirm that the status for the disk mirroring activity is correct (see

Table 84

). To produce a

status report, refer to

“Accessing the RAID status report using Element Manager”

.

Accessing the RAID status report using Element Manager

Use the procedure in this section to display a status report that summarizes primary master and
mirror master hard disk installation and operational information. The status report is valid only for
systems equipped with a RAID configuration.

To access the RAID status report

1

Open Element Manager.

2

From the Administration tab, click System Status, and then click Disk Mirroring.

Table 84 Status field descriptions

Status field

Description

DupliWin.dll Version

Read-only field that displays the RAID software version. The latest load always has
the latest RAID software.

Primary Master Status

Read-only field that displays the status of the primary master disk (Passed/Failed/
NA).

•

If the field indicates Passed, the drive is operating normally

•

If the field indicates Failed, check the power and IDE ribbon cable connections
or replace the faulty hard disk

•

If the field indicates N/A (not available), check the hard disk power and IDE
ribbon cable connections

Mirror Master Status

Read-only field that displays the status of the mirror master disk (Passed/Failed/
NA)

•

If the field indicates Passed, the drive is operating normally

•

If the field indicates Failed, check the power and IDE ribbon cable connections
or replace the failed hard disk

•

If the field indicates N/A (not available), check the hard disk power and IDE
ribbon cable connections

Rebuild

Read-only field that displays the mirror data rebuild progress (idle/started)

Note: You must ensure the system status monitor service is enabled to monitor primary
master and mirror master disk operation and disk mirroring activity.