Nortel Networks BCM200/400 User Manual

Page 233

Advertising
background image

Chapter 19 System monitoring and troubleshooting

233

BCM200/400 4.0 Installation and Maintenance Guide

To monitor RAID disk mirror operational status

1

Open Element Manager.

2

From the Administration tab, click System Status, and then click Disk Mirroring.

The Disk Mirroring screen displays.

3

Click on the Status tab

The Disk Mirroring screen displays the operational status of primary master and mirror master
disks.

4

Confirm that the status for the disk mirroring activity is correct (see

Table 84

). To produce a

status report, refer to

“Accessing the RAID status report using Element Manager”

.

Accessing the RAID status report using Element Manager

Use the procedure in this section to display a status report that summarizes primary master and
mirror master hard disk installation and operational information. The status report is valid only for
systems equipped with a RAID configuration.

To access the RAID status report

1

Open Element Manager.

2

From the Administration tab, click System Status, and then click Disk Mirroring.

Table 84 Status field descriptions

Status field

Description

DupliWin.dll Version

Read-only field that displays the RAID software version. The latest load always has
the latest RAID software.

Primary Master Status

Read-only field that displays the status of the primary master disk (Passed/Failed/
NA).

If the field indicates Passed, the drive is operating normally

If the field indicates Failed, check the power and IDE ribbon cable connections
or replace the faulty hard disk

If the field indicates N/A (not available), check the hard disk power and IDE
ribbon cable connections

Mirror Master Status

Read-only field that displays the status of the mirror master disk (Passed/Failed/
NA)

If the field indicates Passed, the drive is operating normally

If the field indicates Failed, check the power and IDE ribbon cable connections
or replace the failed hard disk

If the field indicates N/A (not available), check the hard disk power and IDE
ribbon cable connections

Rebuild

Read-only field that displays the mirror data rebuild progress (idle/started)

Note: You must ensure the system status monitor service is enabled to monitor primary
master and mirror master disk operation and disk mirroring activity.

Advertising