Installing a bcm200 standard power supply, To install a bcm200 standard power supply – Nortel Networks BCM200/400 User Manual

Page 286

Advertising
background image

286

Chapter 23 Replacing or upgrading a power supply

N0060612

N0060612

11 Remove the four power supply chassis screws from the back of the main unit (see

Figure 137

).

Place the screws in a safe location.

Figure 137 Remove the BCM200 power supply screws

12 Separate the power supply cable from the hard disk cable. Cut the tie-wrap that secures the

power supply cable to the hard disk cable (see

Figure 139

).

13 Remove the power supply from the interior of the main unit.

Installing a BCM200 standard power supply

Use this procedure to install a functional standard power supply in a BCM200 main unit. The I/O
card must be removed from the main unit before you perform this procedure. The base function
tray must be partially removed.

To install a BCM200 standard power supply

1

Obtain and use only the power supply recommended by Nortel.

2

Place the new power supply into the main unit.

Note: Remove the power supply carefully. Ensure the power supply cables are not
entangled or connected to any internal components.

Warning: Protect the hardware components against damage from electrostatic discharge.
Always wear a grounded wrist strap before you handle components. Always place the
components in a static-free container.

Warning: Power supply cable management is critical. Loose or incorrectly positioned
cables can result in cable damage.

Advertising