Mounting the ata2, To connect the ata2, Figure 83 – Nortel Networks BCM200/400 User Manual

Page 177

Advertising
background image

Chapter 11 Installing the analog terminal adapter

177

BCM200/400 4.0 Installation and Maintenance Guide

Figure 83 ATA2 top view

Figure 84

shows the pin-outs for the connection cables.

Figure 84 ATA2 pin-outs

To connect the ATA2

1

Connect one end of a line cord to the ATA2 terminal jack.

2

Connect the other end to your telephone, modem, or fax machine.

3

Connect one end of a line cord to the ATA2 line jack.

4

Connect the other end to an available station port on the BCM main unit or expansion unit.

5

For a 120 V or 230 V system, plug the DIN connector of the power supply cord into the power
supply connector receptacle. Plug the adapter into a standard AC outlet.

Mounting the ATA2

After the ATA2 is correctly connected, you can mount the unit on a wall, as described in this
section.

Caution: In North America, the ATA2 must be powered from a Class 2 power source that
is UL- and CSA-approved.

In Europe, the ATA2 must be powered from a Class II power source that is CE marked.

=

24 V

~

0.006 A

Terminal jack

Line jack

Power supply connector receptacle

TCM*
TCM*

Ring (B-Lead)
Tip (A-Lead)

Line jack

Terminal jack

* The TCM input is not polarity sensitive.

Advertising