Removing a bcm200 cooling fan, To remove a bcm200 cooling fan – Nortel Networks BCM200/400 User Manual

Page 337

Advertising
background image

Chapter 25 Replacing or installing a cooling fan

337

BCM200/400 4.0 Installation and Maintenance Guide

5

Restore the BCM system to operation. For details, refer to

“Restarting the system after

maintenance” on page 240

.

The BCM system starts up when you connect the AC power cord. The start-up process takes
several minutes to complete.

6

Test the direction of the fan exhaust air flow to determine if the fan is correctly installed.

a

Hold a piece of paper or your hand close to the fan exhaust. A correctly installed fan blows
air away from the main unit. If you are testing two fans, cover one fan at a time with your
hand.

b

If the fan exhaust air flow is incorrect, remove the cooling fan (see

“Removing a BCM400

cooling fan” on page 332

) and reinstall the fan in the correct position (this procedure).

Removing a BCM200 cooling fan

Use this procedure to remove the cooling fan in a BCM200 main unit.

To remove a BCM200 cooling fan

1

Shut down the system (see

“Performing a system shutdown” on page 239

).

2

Disconnect the BCM system from the AC power outlet.

3

Attach one end of the grounding strap to your wrist and the other end to a grounded metal
surface.

4

Remove the top cover from the main unit (see

“Installing the main unit top cover” on page

254

).

5

Disconnect the I/O card fan cable connection (see

Figure 185 on page 338

).

Warning: Protect the hardware components against damage from electrostatic discharge.
Always wear a grounded wrist strap before you handle components. Always place the
components in a static-free container.