Toshiba Tosvert VF-AS1 User Manual

Page 162

Advertising
background image

E6581301

F-50

6

Setting parameters

a) Operating method: Terminal input

Set the command mode selection EOQF to .

b) Use the S2 and S3 terminals for switching. (Instead, other terminals may be used.)

S2: Acceleration/deceleration switching signal 1
S3: Acceleration/deceleration switching signal 2

Title

Function

Adjustment range

Example of setting

H

Input terminal function selection 6 (S2)



~



(Acceleration/deceleration

switching signal 1)

H

Input terminal function selection 7 (S3)



~



(Acceleration/deceleration

switching signal 2)

Acceleration/deceleration pattern

Acceleration/deceleration patterns can be selected individually, using the acceleration/deceleration 1, 2, 3 and 4
parameters.

1) Straight acceleration/deceleration
2) S-pattern acceleration/deceleration 1
3) S-pattern acceleration/deceleration 2

Title

Function

Adjustment range

Default setting

H

Acceleration/deceleration 1 pattern



:Straight, :S-pattern 1, :S-pattern 2



H

Acceleration/deceleration 2 pattern



:Straight, :S-pattern 1, :S-pattern 2



H

Acceleration S-pattern lower limit
adjustment



~%



H

Acceleration S-pattern upper limit
adjustment



~%



H

Deceleration S-pattern lower limit
adjustment



~%



H

Deceleration S-pattern upper limit
adjustment



~%



H

Acceleration/deceleration 3 pattern



:Straight, :S-pattern 1, :S-pattern 2



H

Acceleration/deceleration 4 pattern



:Straight, :S-pattern 1, :S-pattern 2



1) Straight acceleration/deceleration
A general acceleration/deceleration pattern.
This pattern can usually be used.

CEE

Output frequency [Hz]

FGE

Maximum frequency HJ

Time [s]

0

2) S-pattern acceleration/deceleration 1
Select this pattern to accelerate/decelerate the motor rapidly to a high-speed region with an output frequency of
60Hz or more or to minimize the shocks applied during acceleration/deceleration. This pattern is suitable for
conveyer machines.

Actual acceleration time

CEE

H × CEE %

H × CEE %

Time [s]

Output frequency [Hz]

0

Maximum frequency

HJ

Set frequency

FGE

Actual deceleration time

Maximum frequency

HJ

Set frequency

H × FGE %

H × FGE %

Time [s]

Output frequency [Hz]

0

+

Both the S-pattern lower-limit setting (H, H) and the S-pattern upper limit setting (H, H)
affect all acceleration/deceleration pattern settings.

Advertising