Toshiba Tosvert VF-AS1 User Manual

Page 198

Advertising
background image

E6581301

G-4

7

Table of setting of contact input terminal function

Parameter setting

Parameter setting

Positive

logic

Negative

logic

Function

Positive

logic

Negative

logic

Function





No function is assigned





Servo lock signal





F: Forward run command





Simple positioning (positioning loop)





R: Reverse run command





Integrating wattmeter display clear





ST: Standby





Trace back trigger signal





RES: Reset





Light-load high-speed operation
prohibitive signal





S1: Preset speed 1





No function assigned





S2: Preset speed 2





No function assigned





S3: Preset speed 3





No function assigned





S4: Preset speed 4





Binary data write





Jog run





Up/down frequency (up)

*1





Emergency stop





Up/down frequency (down)

*1





DC braking





Up/down frequency (clear)





Acceleration/deceleration switching 1





No function assigned





Acceleration/deceleration switching 2





No function assigned





V/f switching signal 1





Forward/reverse selection





V/f switching signal 2





Run/stop command

*3





Torque limit switching signal 1





Commercial power/INV switching





Torque limit switching signal 2





Frequency reference priority switching





PID control OFF selection





VI/II terminal priority





Pattern operation group 1





Command terminal board priority





Pattern operation selection 2





Permission of parameter editing





Pattern operation continuation signal





Control switching (speed/torque)





Pattern operation trigger signal





No function assigned





External thermal error





No function assigned





Forced switching from communication to local





No function assigned





HD operation retention





No function assigned





PID differentiation/integration clear





Rapidest deceleration command





PID forward/reverse switching





Preliminary excitation

*4





Forced continuous operation





Braking request





Specified speed operation





No function assigned





Acceleration/deceleration suspend
signal





Brake answer back input





Power failure synchronized signal





No function assigned





My function RUN signal





Traverse permission signal





Auto-tuning signal





Speed gain switching

*1: Valid when HOQF(Frequency setting mode selection 1) is set at  (Up/down frequency).

The frequency setting range is between =~WN(Upper limit frequency). The acceleration/deceleration time
with respect to the frequency setting remains CEE/FGE, unless switching between acceleration and
deceleration is performed.

*2: To switch acceleration/deceleration pattern, V/f pattern, torque limit 1~4, give the following signals to switching

functions.

*3: If , (F: Forward run command) or ,  (R: Reverse run command) is assigned at the same time, this

function has a priority.

*4: After the motor slows down and comes to a full stop at a pre-excitation command, the motor is set free

momentarily to bring it into a pre-excitation state.
This function should not be used when H is set to  or 4. Or the inverter might malfunction.

Switching signal 1

Switching signal 2

Acceleration/deceleration, V/f, torque limit 1

OFF

OFF

Acceleration/deceleration, V/f, torque limit 2

ON

OFF

Acceleration/deceleration, V/f, torque limit 3

OFF

ON

Acceleration/deceleration, V/f, torque limit 4

ON

ON

Advertising