Toshiba Tosvert VF-AS1 User Manual

Page 185

Advertising
background image

E6581301

F-73

6

[Setup values of H~H]

Default setting

Communication

No.

Trace (monitor) function

Communication

unit at tracing



FD00

Output frequency

0.01Hz



FD02

Frequency command value

0.01Hz



FD03

Output current

0.01%



FD04

Input voltage (DC detection)

0.01%



FD05

Output voltage

0.01%



FD15

Compensated frequency

0.01Hz



FD16

Speed feedback (real-time value)

0.01Hz



FD17

Speed feedback (1-second filter)

0.01Hz



FD18

Torque

0.01%



FD19

Torque command

0.01%



FD20

Torque current

0.01%



FD21

Exciting current

0.01%



FD22

PID feedback value

0.01%



FD23

Motor overload factor (OL2 data)

0.01%



FD24

Inverter overload factor (OL1 data)

0.01%



FD25

Regenerative braking resistance overload factor (OLr data)

0.01%



FD28

Regenerative braking resistor load factor (% ED)

0.01%



FD29

Input power

0.01kW



FD30

Output power

0.01kW



FE39

Optional AI2 input

0.01%



FE35

RR/S4 input

0.01%



FE36

VI/II input

0.01%



FE37

RX input

0.01%



FE38

Optional AI1 input

0.01%



FE40

FM output

0.01%



FE41

AM output

0.01%



FE76

Integral input power

0.01kwhr



FE77

Integral output power

0.01kwhr



FE60

My function monitor 1

1c



FE61

My function monitor 2

1c



FE62

My function monitor 3

1c



FE63

My function monitor 4

1c

Acquisition of trace data

Trace data is acquired through a communication device.
The VF-AS1 supports the communication standards and protocols listed below. (Built-in option)

• RS485 (MODBUS-RTU) …TOSHIBA protocol
• USB…TOSHIBA protocol
• CC-Link
• PROFIBUS
• DeviceNet

⇒ For details of each option and command, refer to the instruction manual for each communication device.