Toshiba Tosvert VF-AS1 User Manual
Page 93

E6581301
E-27
5
[Terminal FM-related parameters]
Title
Function
Adjustment range
Adjustment
level
Default setting
HOUN
FM terminal meter selection
: Output frequency
: Frequency command value
: Output current
: Input voltage (DC detection)
: Output voltage
: Compensated frequency *2
: Speed feedback (real-time value)
: Speed feedback (1 second filter)
: Torque
: Torque command
: Torque current
: Exiting current
: PID feedback value
: Motor overload factor (OL2 data)
: Inverter overload factor (OL1 data)
: Regenerative braking resistance
overload factor (OLr data)
: Regenerative braking resistor load
factor (% ED)
: Input power
: Output power
: Optional AI2 input
: RR/S4 input
: VI/II input
: RX input
: Optional AI1 input
: FM output (Do not select this option.)
: AM output
: Fixed output 1
: Communication data output
: Fixed output 2
: Fixed output 3
: Cumulative input power
: Cumulative output power
: Gain display
: My function monitor 1
: My function monitor 2
: My function monitor 3
: My function monitor 4
: Signed output frequency
: Signed frequency command value
: Signed compensated frequency
: Signed speed feedback
(real-time value)
: Signed speed feedback
(1 second filter)
: Signed torque
: Signed torque command
: Signed torque current
: Signed PID feedback value
: Signed RX input
: Signed optional AI1 input
: Signed fixed output 1
: Signed fixed output 2
: Signed fixed output 3
(a)
(a)
(b)
(c)
(c)
(a)
(a)
(a)
(d)
(d)
(b)
(b)
(a)
(a)
(a)
(a)
(a)
(b)
(b)
(a)
(a)
(a)
(a)
(a)
(a)
(a)
–
–
–
–
(a)
(a)
–
*1
*1
*1
*1
(a)
(a)
(a)
(a)
(a)
(d)
(d)
(b)
(a)
(a)
(a)
–
–
–
HO
FM terminal meter adjustment –
–
H
FM voltage/current output
switching
:Voltage output (0~10V), :Current output (0~20mA)
H
FM output gradient
characteristic
:Negative gradient (downward-sloping),
:Positive gradient (upward-sloping)
H
FM bias adjustment
–~%
*1: Monitor adjustment level selected.
*2: “Compensated frequency” refers to the frequency actually sent from an inverter to the motor connected.