Toshiba Tosvert VF-AS1 User Manual

Page 73

Advertising
background image

E6581301

E-7

5

<Frequency setting mode selection>

[Parameter setting]

Title

Function

Adjustment range

Default setting

HOQF

Frequency setting mode
selection 1



:VI/II (voltage/current input)



:RR/S4 (potentiometer/voltage input)



:RX (voltage input)



:Operation panel input enabled (including

LED/LCD option input)



:2-wire RS485 communication input



:4-wire RS485 communication input



:Communication option input



:Optional AI1 (differential current input)



:Optional AI2 (voltage/current input)



:Up/Down frequency



:Optional RP pulse input



:Optional high-speed pulse input



:Optional binary/BCD input



[Programmed value]



:

VI/II input

Speed setting commands are entered by external signals (0~10Vdc or

4(0)~20mAdc).



:

RR/S4 input

Speed setting commands are entered by external signals (RR/S4
terminal:0~10Vdc).



:

RX input

Speed setting commands are entered by external signals (RX terminal:0~±10Vdc
(±5Vdc)).



:

Operation panel input

Press the and keys on the operation panel to set the
frequency.
(including LED/LCD option input)



:

2-wire RS485 communication operation

Speed commands are entered from the 2-wire
RS485 communications device.
(Communication No.:FA01)



:

4-wire RS485 communication operation

Speed commands are entered from the 4-wire RS485
communications device.
(Communication No.:FA05)



:

Communication option input enabled

Speed commands are entered from an optional
communication device.

For details, refer to Instruction Manual (E6581281,

E6581343, E6581288) specified in Section 6.41.



:

AI1 input

Speed setting commands are entered by external signals (AI1 terminal (option):
0~±10Vdc (±5Vdc)).



:

AI2 input

Speed setting commands are entered by external signals (AI2 terminal: 0~10Vdc
or 4(0)~20mAdc) (optional).



:

Up/Down frequency

Speed commands are entered by means of Up/Down frequency signals
from the terminal board.

Refer to Section 7.2.



:

RP pulse input

Speed commands are entered by means of RP pulses (optional).



:

High-speed pulse input

Speed commands are entered by means of high-speed pulses
(optional).



:

Binary code entry/BCD entry

Speed commands are entered by means of 12/16-bit binary
codes (optional) or BCD (optional).

Advertising