Toshiba Tosvert VF-AS1 User Manual

Page 186

Advertising
background image

E6581301

F-74

6

Trace data communication number

Communication

No.

Function

Minimum setting

/readout unit

Setting/readout range

Default setting

E000

Trace data 1 pointer
(For H)



/



~ (correspond to E100

to E199)



E001

Trace data 2 pointer
(For H)



/



~ (correspond to E200

to E299)



E002

Trace data 3 pointer
(For H)



/



~ (correspond to E300

to E399)



E003

Trace data 4 pointer
(For H)



/



~ (correspond to E400

to E499)



E100

Data 1 of trace data 1



/



~HHHH



Data 2~99 of trace data 1



/



~HHHH



E199

Data 100 of trace data 1



/



~HHHH



E200

Data 1 of trace data 2



/



~HHHH



Data 2~99 of trace data 2



/



~HHHH



E299

Data 100 of trace data 2



/



~HHHH



E300

Data 1 of trace data 3



/



~HHHH



Data 2~99 of trace data 3



/



~HHHH



E399

Data 100 of trace data 3



/



~HHHH



E400

Data 1 of trace data 4



/



~HHHH



Data 2~99 of trace data 4



/



~HHHH



E499

Data 100 of trace data 4



/



~HHHH



Communication numbers E000 to E003 are automatically incremented by the inverter when data is traced
continuously.
* In ordinary cases, these parameters do not need to be rewritten.

Ex.) When operation frequency data is acquired through a communication device
Data acquired

(H) h=8000

⇒ 8000×0.01Hz=80.0Hz