E6581301

F-63

6

6.34

Override

H

: Override addition input selection

H

: Override multiplication input selection

• Function

These parameters are used to adjust reference frequencies by means of external input.

Title

Function

Adjustment range

Default setting

H

Override addition input selection
[Hz]



:Disabled



:VI/II (voltage/current input)



:RR/S4 (potentiometer/voltage input)



:RX (voltage input)



:Operation panel input enabled (including

LED/LCD option input)



:2-wire RS485 input enabled



:4-wire RS485 input enabled



:Communication option input enabled



:Optionl AI1 (differential current input)



:Optionl AI2 (voltage/current input)



:Up/Down frequency



:Optionl RP pulse input



:Optionl high-speed pulse input



:Optionl binary/BCD input



H

Override multiplication input
selection
[%]



:Disabled



:VI/II (voltage/current input)



:RR/S4 (potentiometer/voltage input)



:RX (voltage input)



:H



:Optionl AI1



The override functions calculate output frequency by the following expression:

Frequency command value × (1+

)+Value [Hz] selected with H

1) Additive override

In th1is mode, an externally input override frequency is added to operation frequency command.
[Ex.1: RR/S4 (Reference frequency), VI/II (Override input)] [Ex.2:RX (Reference frequency), VI/II (Override input)]

Output frequency

Over-ridden frequency

Override

(VI/II input)

0

10V

Over-ridden frequency

HJ

Override

(VI/II input)

0

10V

HJ

RR/S4 input
(Reference
frequency)

(

)

RX input
(Reference
frequency)

(

)

Output frequency

Reverse run

Forward run

Value [%] selected with H

100