Toshiba Tosvert VF-AS1 User Manual
Page 260

K-22
E6581301
11
[23] Pattern operation [3/3]
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
H
0570
Preset speed operation frequency
10 operation mode
Ditto
1/1
0
Disabled
●/●
-
●
●
5. 12
H
0571
Preset speed operation frequency
11 operation mode
Ditto
1/1
0
Disabled
●/●
-
●
●
5. 12
H
0572
Preset speed operation frequency
12 operation mode
Ditto
1/1
0
Disabled
●/●
-
●
●
5. 12
H
0573
Preset speed operation frequency
13 operation mode
Ditto
1/1
0
Disabled
●/●
-
●
●
5. 12
H
0574
Preset speed operation frequency
14 operation mode
Ditto
1/1
0
Disabled
●/●
-
●
●
5. 12
H
0575
Preset speed operation frequency
15 operation mode
Ditto
1/1
0
Disabled
●/●
-
●
●
5. 12
[24] Protection functions [1/3]
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
H
0601
Stall prevention level
0~164%, 165:Deactivated
1/1
150
Enabled
●/●
-
●
●
6. 33. 1
H
0602
Inverter trip record retention
selection
0:Clear when power is turned off
1:Retain even after power is turned off
1/1
0
Enabled
●/●
●/●
●
●
6. 33. 2
H
0603
Emergency stop
0:Coast stop
1:Deceleration stop
2:Emergency DC braking
3:Deceleration stop (deceleration 4)
1/1
0
Disabled
●/●
●/●
●
●
6. 33. 3
H
0604
Emergency DC braking control
time
0.0~20.0 sec.
0.1/0.1
1.0
Enabled
●/●
●/●
●
●
6. 33. 3
H
0605
Output phase failure detection
selection
0:Deselect
1:At starting (only one time after power is turned
on)
2:At starting (each time power is turned on)
3:During operation
4:At starting + during operation
5:Output cut-off detection enabled
1/1
0
Disabled
●/●
●/●
●
●
6. 33. 4
H
0606
OL reduction starting frequency
0.0~30.0Hz
0.1/0.01
6.0
Enabled
●/●
●/●
●
●
5. 14
H
0607
Motor 150%-overload time limit
10~2400 sec.
1/1
300
Enabled
●/●
●/●
●
●
5. 14
H
0608
Input phase failure detection
mode selection
0:Deselect
1:Select
1/1
1
Disabled
●/●
●/●
●
●
6. 33. 7
H
0609
Low current detection current
hysteresis width
1~20%
1/1
10
Enabled
●/●
●/●
●
●
6. 33. 8
H
0610
Low current trip selection
0:No trip, 1:Trip
1/1
0
Enabled
●/●
●/●
●
●
6. 33. 8
H
0611
Low current detection current
0~100%
1/1
0
Enabled
●/●
●/●
●
●
6. 33. 8
H
0612
Low current detection time
0~255 sec.
1/1
0
Enabled
●/●
●/●
●
●
6. 33. 8
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)