K-22

E6581301

11

[23] Pattern operation [3/3]

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control V/f Constant Reference

H

0570

Preset speed operation frequency

10 operation mode

Ditto

1/1

0

Disabled

●/●

-

5. 12

H

0571

Preset speed operation frequency

11 operation mode

Ditto

1/1

0

Disabled

●/●

-

5. 12

H

0572

Preset speed operation frequency

12 operation mode

Ditto

1/1

0

Disabled

●/●

-

5. 12

H

0573

Preset speed operation frequency

13 operation mode

Ditto

1/1

0

Disabled

●/●

-

5. 12

H

0574

Preset speed operation frequency

14 operation mode

Ditto

1/1

0

Disabled

●/●

-

5. 12

H

0575

Preset speed operation frequency

15 operation mode

Ditto

1/1

0

Disabled

●/●

-

5. 12

[24] Protection functions [1/3]

Vector control

Title

Communi

cation

No.

Function

Adjustment range

Minimum

setting unit

(Panel/Communi

cation)

Default

setting

Write during

running

Speed

control

Torque

control

PM

control V/f Constant Reference

H

0601

Stall prevention level

0~164%, 165:Deactivated

1/1

150

Enabled

●/●

-

6. 33. 1

H

0602

Inverter trip record retention

selection

0:Clear when power is turned off

1:Retain even after power is turned off

1/1

0

Enabled

●/●

●/●

6. 33. 2

H

0603

Emergency stop

0:Coast stop

1:Deceleration stop

2:Emergency DC braking

3:Deceleration stop (deceleration 4)

1/1

0

Disabled

●/●

●/●

6. 33. 3

H

0604

Emergency DC braking control

time

0.0~20.0 sec.

0.1/0.1

1.0

Enabled

●/●

●/●

6. 33. 3

H

0605

Output phase failure detection

selection

0:Deselect

1:At starting (only one time after power is turned

on)

2:At starting (each time power is turned on)

3:During operation

4:At starting + during operation

5:Output cut-off detection enabled

1/1

0

Disabled

●/●

●/●

6. 33. 4

H

0606

OL reduction starting frequency

0.0~30.0Hz

0.1/0.01

6.0

Enabled

●/●

●/●

5. 14

H

0607

Motor 150%-overload time limit

10~2400 sec.

1/1

300

Enabled

●/●

●/●

5. 14

H

0608

Input phase failure detection

mode selection

0:Deselect

1:Select

1/1

1

Disabled

●/●

●/●

6. 33. 7

H

0609

Low current detection current

hysteresis width

1~20%

1/1

10

Enabled

●/●

●/●

6. 33. 8

H

0610

Low current trip selection

0:No trip, 1:Trip

1/1

0

Enabled

●/●

●/●

6. 33. 8

H

0611

Low current detection current

0~100%

1/1

0

Enabled

●/●

●/●

6. 33. 8

H

0612

Low current detection time

0~255 sec.

1/1

0

Enabled

●/●

●/●

6. 33. 8

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)

Sensorless vector/vector with sensor (●:Effective, -:Ineffective)