K-46 – Toshiba Tosvert VF-AS1 User Manual

Page 284

Advertising
background image

K-46

E6581301

11

Standard default settings classified by inverter model (capacity)

Inverter type

Torque

boost

XD

H
H
H

Base

frequency

voltage

XNX

H
H
H

Acc/dec

time

CEE

/FGE

H

/H

H

/H

H

/H

PWM Carrier

frequency

EH

Dynamic

braking

resistance

RDT

Allowable

continuous

braking

resistance

RDER

Inverter side

switching

waiting time

H

Motor rated

capacity

H

Motor rated

current

H

Motor rated

revolutions

H

*1

Motor

constant 1

(torque

boost)

H

Motor

constant 2

(no load

current)

H

Motor

constant 3

(leak

inductance)

H

Motor

constant 4

(rated slip)

H

VFAS1

2 0 0 4 P L





























VFAS1

2 0 0 7 P L





























VFAS1

2 0 1 5 P L





























VFAS1

2 0 2 2 P L





























VFAS1

2 0 3 7 P L





























VFAS1

2 0 5 5 P L





























VFAS1

2 0 7 5 P L





























VFAS1

2 11 0 P M





























VFAS1

2 1 5 0 P M





























VFAS1

2 1 8 5 P M





























VFAS1

2 2 2 0 P M





























VFAS1

2 3 0 0 P M





























VFAS1

2 3 7 0 P M





























VFAS1

2 4 5 0 P M





























VFAS1

2 5 5 0 P





























VFAS1

2 7 5 0 P





























VFAS1

4 0 0 7 P L



*2

























VFAS1

4 0 1 5 P L



*2

























VFAS1

4 0 2 2 P L



*2

























VFAS1

4 0 3 7 P L



*2

























VFAS1

4 0 5 5 P L



*2

























VFAS1

4 0 7 5 P L



*2

























VFAS1

4 11 0 P L



*2

























VFAS1

4 1 5 0 P L



*2

























VFAS1

4 1 8 5 P L



*2

























VFAS1

4 2 2 0 P L



*2

























VFAS1

4 3 0 0 P L



*2

























VFAS1

4 3 7 0 P L



*2

























VFAS1

4 4 5 0 P L



*2

























VFAS1

4 5 5 0 P L



*2

























VFAS1

4 7 5 0 P L



*2

























VFAS1

4 9 0 0 P C



*2

























VFA S1 411 0K P C



*2

























VFAS1

4 1 3 2 K P C



*2

























VFAS1

4 1 6 0 K P C



*2

























VFAS1

4 2 0 0 K P C



*2

























VFAS1

4 2 2 0 K P C



*2

























VFAS1

4 2 8 0 K P C



*2

























VFAS1

4 3 5 5 K P C

VFAS1

4 4 0 0 K P C

VFAS1

4 5 0 0 K P C

*1: Factory default settings when the base frequency (XN) is set at 60Hz (50Hz)  *2: Inverter with a model number ending with