Toshiba Tosvert VF-AS1 User Manual
Page 253

K-15
E6581301
11
[16] PID control [2/2]
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f
Reference
H
0363
Integral (I) gain
0.01~100.0
0.01/0.01
0.10
Enabled
●/●
-
●
●
*1
H
0364
PID deviation upper limit
NN
~WN Hz
0.1/0.01
*2
Enabled
●/●
-
●
●
*1
H
0365
PID deviation lower limit
NN
~WN Hz
0.1/0.01
*2
Enabled
●/●
-
●
●
*1
H
0366
Differential (D) gain
0.00~2.55
0.01/0.01
0.00
Enabled
●/●
-
●
●
*1
*1:
⇒ For details, refer to Instruction Manual (E6581329) specified in Section 6.41. *2: Inverter with a model number ending with -WN: 60.0 -WP: 50.0
[17] Speed feedback/positioning control
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control
V/f
Reference
H
0367
Process upper limit
NN
~WN Hz
0.1/0.01
*4
Enabled
-/●
-/●
-
-
*1
H
0368
Process lower limit
NN
~WN Hz
0.1/0.01
NN
Enabled
-/●
-/●
-
-
*1
H
0369
PID control waiting time
0~2400 sec.
1/1
0
Enabled
-/●
-/●
-
-
*1
H
0370
PID output upper limit
NN
~WN Hz
0.1/0.01
*4
Enabled
-
-
-
-
*1
H
0371
PID output lower limit
NN
~WN Hz
0.1/0.01
NN
Enabled
-
-
-
-
*1
H
0372
Process increasing rate (speed type
PID control)
0.1~600.0
0.1/0.1
10.0
Enabled
-
-
-
-
*1
H
0373
Process decreasing rate (speed
type PID control)
0.1~600.0
0.1/0.1
10.0
Enabled
-
-
-
-
*1
H
0375
Number of PG input pulses
12~9999
1/1
500
Disabled
●/●
-/●
-
-
*2
H
0376
Selection of number of PG input
phases
1:Single-phase input
2:Two-phase input
1/1
2
Disabled
●/●
-
-
-
*2
H
0377
PG disconnection detection
0:Deselect
1:Select (with filter)
2:Select (Detection of momentary power failure)
1/1
0
Disabled
●/●
-
-
-
*2
H
0378
Number of RP terminal input
pulses
12~9999
1/1
500
Disabled
●/●
●/●
-
-
*3
H
0381
Simple positioning completion
range
1~4000
1/1
100
Enabled
●/●
-
●
●
*2
*1:
⇒ For details, refer to Instruction Manual (E6581329) specified in Section 6.41. *2: ⇒ For details, refer to Instruction Manual (E6581319) specified in Section 6.41.
*3:
⇒ For details, refer to Instruction Manual (E6581341) specified in Section 6.41. *4: Inverter with a model number ending with -WN: 60.0 -WP: 50.0
[18] Motor constant [1/2]
Vector control
Title
Communi
cation
No.
Function
Adjustment range
Minimum
setting unit
(Panel/Communi
cation)
Default
setting
Write during
running
Speed
control
Torque
control
PM
control V/f Constant Reference
H
0400
Auto-tuning 1
0:No auto-tuning
1:Initialize motor constant (0 after execution)
2:Continue operation continued after auto-tuning (0
after execution)
3:Auto-tuning by input terminal signal
4:Motor constant auto calculation (0 after
execution)
1/1
0
Disabled
●/●
●/●
-
-
6. 22
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)
Sensorless vector/vector with sensor (●:Effective, -:Ineffective)