Toshiba RAS-10SKV-A User Manual

Page 20

Advertising
background image

FILE NO. SVM-07008

– 19 –

6-2. Outdoor Unit (RAS-10SAV-E, RAS-10SAV-A)

No.

Parts name

Model name

Rating

1 SC coil L01 GET-0451 0.6mH, 15A

(Noise filter) L03

GET-0452

2.0 mH, 10A

Primary side DC280V, Secondary

2 DC-DC transformer

SWT-72

side 7.0 V x 1, 12 V x 1, 17V x 2

3 Reactor CH-51-Z-T L=19mH, 10A

4 Outside fan motor

SKF-240-20B-1 20W

5 G5NB-1A Coil DC12V Contact AC250V-1.5A

6

Outside air temp.

(Inverter attached) 10k

(25°C)

sensor

(TO sensor)

7

Heat exchanger temp.

(Inverter attached) 10k

(25°C)

sensor

(TE sensor)

9

JX0-6B 20A, AC250V

Terminal block (6P)

10

11

Fuse

For protection of switching power source 3.15A, AC250V

For protection of inverter input overcurrent 25A, AC250V

12

Electrolytic capacitor LLQ2G501KHUBTF 500

µ

F, DC 400 V x 3 pieces

13

Compressor thermo.

PW-2AL OFF: 125 ± 4°C, ON: 90 ± 5°C

Rectifier

14

Fan control relay

D15XB60-4001

15A, 600V

16 4-way valve coil

AC220-240V

IGBT GT15J321

15A, 600

Compressor DA89X1C-23FZ 3-phases 4-poles 750W

15

8

Dischenge temp.

(Inverter attached) 62k

(20°C)

sensor

(TD sensor)

17 Running capacitor

DS451155NPQB AC 450V~, 1.5

µ

F

(for fan motor)