FILE NO. SVM-07008

11-3. Judgment by Flashing LED of Indoor Unit

While the indoor unit monitors the operation status of the air conditioner, if the protective circuit operates, the
contents of self-diagnosis are displayed with block on the indoor unit indication section.

NOTES:
(1) The contents of items B and C and a part of item E are displayed when air conditioner operates.
(2) When item B and C, and item B and a part of item E occur concurrently, priority is given to the block of item B.
(3) The check codes can be confirmed on the remote control for servicing.

Table 11-3-1

OPERATION (Green)

Flashing display (1 Hz)

OPERATION (Green)

TIMER (Yellow)

PRE DEF. (Orange)

Flashing display (5 Hz)

OPERATION (Green)

PRE DEF. (Orange)

Flashing display (5 Hz)

OPERATION (Green)

TIMER (Yellow)

Flashing display (5 Hz)

OPERATION (Green)

Flashing display (5 Hz)

Protective circuit operation for indoor P.C. board

Protective circuit operation for connecting cable

and serial signal system

Protective circuit operation for outdoor P.C. board

Protective circuit operation for others

(including compressor)

Power failure (when power is ON)

Indoor indication

lamp flashes.

Which lamp

does flash?

Item

A

B

C

D

E

Check

code

Block display

Description for self-diagnosis