Advertising
background image

– 76 –

FILE NO. SVM-07008

1

Room temp. (TA) sensor
Heat exchanger (TC) sensor

2

Remote control

3

Louver motor
24BYJ48

4

Indoor fan motor

Disconnect the connector and measure the resistance value with tester.
(Normal temp.)

To item of How to judge whether remote control is good or bad of the Judgment
of trouble by symptom.

Measure the resistance value of each winding coil by using the tester.
(Under normal temp. 25°C)

Since judgment of DC motor is difficult on the single motor, refer to 10-5-1. (3)

11-8-3. Indoor unit (Other parts)

No.

Part name

Checking procedure

11-8-4. Outdoor unit

1 Compressor

(Model : DA89X1C-23FZ)

Sensor

TA, TC (k

)

20.7

12.6

10.0

7.9

4.5

5

4

3

2

1

White

Yellow

Yellow

Yellow

Yellow

5

4

3

2

1

No.

Part name

Checking procedure

Position

Resistance value

1 to 2

1 to 3

380±40

1 to 4

1 to 5

Temperature

10°C 20°C 25°C 30°C 40°C

Measure the resistance value of winding by using the tester.

For details, refer to Section 10-9.

White Black

Red

Position

Resistance value

Red - White

White - Black 1.1

Black - Red

Measure the resistance value of each winding by using the tester.

Under 20°C

Outdoor fan motor

(Model : SKF-240-20B-1)

N

Red

White

C1.5 mF

450V

Black

Position

Resistance value

White - Black

2

Black - Red

260.1

235.2

Advertising
This manual is related to the following products: