Toshiba RAS-10SKV-A User Manual

Page 40

Advertising
background image

Item

14. QUIET mode

Operation flow and applicable data, etc.

Description

When the [QUIET] button is pressed, the fan of the
indoor unit will be restricted the revolving speed at

until the [QUIET] button is pressed once

Remarks :
1. Quiet mode is unable to work in dry mode.
2. Quiet mode is appropriate to work with less

cooling load and less heating load condition.

Quiet mode is the system which, control the
revolving speed of indoor fan to work
constantly at lower than speed L. In addition,
noise level of indoor unit is less than usual.

speed L

again (cancel Quiet mode).

Because of the fan speed L- may cause not
enough the cooling capacity or heating

15. COMFORT The principles of comfort sleep mode are:

Quietness for more comfortable. When

Save energy by changing room temperature

The air condition can shut down by itself

Remarks:

1. Comfort sleep mode will not operate in dry

automatically.

mode and fan only mode.

automatically.

room temperature reach setting temperature

Cooling mode

The preset temperature will increase as
show on ECO operation (Item No. 9)

Press the [COMFORT SLEEP] button to

choose the operating hours. Repeat

pressing to select the hours.

If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.

Heating mode

The preset temperature will drop down as
show on ECO operation (Item No. 9)

choose the operating hours. Repeat

Press the [COMFORT SLEEP] button to

pressing to setect thehours.

If the [COMFORT SLEEP] button is pressed
again means cancel comfort sleep mode.

(1hr, 3hr, 5hr or 9hr)

(1hr, 3hr, 5hr or 9 hr)

16. One-Touch

39

capacity.

SLEEP mode

Operation condition for model to Europe
market

When an indoor unit receives "One Touch
Comfort Signal" from the remote controller,

the indoor unit operates as following.

1) Air conditioner starts to operation when

the signal is received, even if the air

conditioner was OFF.

2) Operation mode is set according to room

temperature, the same as AUTO mode.

3) Target temperature is 24ºC.

4) Louver position is set as stored position

of the operating mode.

5) Fan is controlled as followings.

One touch comfort is the fully automated operation
that is set according to the preferable condition in
a region.

0

12

25

AUTO

*AUTO/L

L

Fan

Operation

Time after operation

starts (min)

*AUTO/L: Fan operates depends on the setting
temperature and room temperature.

During the One Touch Comfort mode if the indoor
unit receives any signal with other operation mode,
the unit will cancel the comfort mode and operates
according to the signal received.

Comfort

FILE NO. SVM-07008

Advertising
This manual is related to the following products: