Toshiba RAS-10SKV-A User Manual

Page 36

Advertising
background image

35

Item

9. Temporary

operation

Operation flow and applicable data, etc.

Pressing [RESET] button starts the temporary opera-
tion of [AUTO] operation. When keeping [RESET]
button pressed for 10 seconds or more, the temporary
[COOL] operation is performed.

Description

1) When pressing [RESET] button, the

temporary [AUTO] operation starts.

2) When keeping [RESET] button pressed

for 3 seconds or more, Pi, Pi, Pi sound is
heard and [AUTO RESTART] control is
changed.

3) When keeping [RESET] button pressed

for 10 seconds or more, “Pi” sound is
heard and the temporary [COOL]
operation starts.

4) If the filter lamp goes on, press [RESET]

button to go off the filter lamp, and then
press [RESET] button again.

5) To stop the temporary operation, press

the button again.

Filter lamp ON

Press RESET button.

Did you press [RESET] button

for 3 seconds or more?

Did you press [RESET] button

for 10 seconds or more?

Switch to [AUTO RESTART] control.

YES

YES

NO

NO

NO

YES

Temporary [AUTO] operation

Temporary [COOL] Operation

10. Discharge temperature control 1. Purpose

This function detects error on the
refrigerating cycle or error on the com-
pressor, and performs protective control.

2. Operation

• Control of the compressor speed

The speed control is performed as
described in the left table based upon
the discharge temperature.

Td value

117°C

112°C

108°C

105°C

98°C

Control operation

Judges as an error and stops the compressor.

Reduce the compressor speed.

Reduce slowly compressor speed.

Keeps the compressor speed.

If the operation is performed with lower speed than one
commanded by the serial signal, speed is slowly raised
up to the commanded speed.

Operates with speed commanded by the serial signal.