47

FILE NO. SVM-07008

10-1-1. Installation Diagram of Indoor and Outdoor Units

Shield pipe

Air filte

r

Hook

Hook

(Attach

to the f

ront p

anel.)

65 mm or more

170 m

m or m

ore

1

Installation plate

170 mm or more

2

Wireless remote

5

Super Oxi

6

Super Sterilizer

3

Batteries

4

Remote control holder

8

Pan head

wood screw

The auxiliary piping can be

connected to the left, rear left,

rear right, right, bottom right

or bottom left.

Insulate the refrigerant pipes

separately with insulation, not

together.

6 mm thic k heat resisting

pol yethylene f oam

Rear

left

Left

Bottom left

Right

Rear right

Bottom

right

Wall

Do not allow the drain hose to

get slack.

Make sure to run the drain

hose sloped downward.

Cut the piping

hole sloped

slightly .

For the rear left and left piping

Insert the cushion between

the indoor unit and wall, and

tilt the indoor unit for better

operation.

100 mm o

r more

45 mm

or more

400

mm

or m

ore

Saddle

Vinyl tape

Apply after carrying

out a draina ge test.

600 mm

or more

Extension drain hose

(Not available, provided

by installer)

600 mm or more

Before installing the wireless remote controller

• Loading Batteries

1. Remove the battery cover.

2. Insert 2 new batteries (AAA type)

following the (+) and (- ) positions.

3 Batteries

2 Wireless remote controller

AC

L

filter

Deo filter

10. INSTALLATION PROCEDURE