Toshiba RAS-10SKV-A User Manual

Page 34

Advertising
background image

Horizontal

blowing

Inclined
blowing

Blowing

downward

Air direction

Inclined
blowing

Horizontal

blowing

Initial setting of "Cooling storage position"

Louver : Directs downward (48°)

Heating operation/

AUTO (HEAT)

Initial setting of “Heating storage position”
Louver : Directs downward (115.7˚)

Item

7. Louver control

1) Louver

position

Operation flow and applicable data, etc.

This function controls the air direction of the indoor unit.

Description

• Swing operation is performed in width 35° with the stop position as

the center.

• If the stop position exceeds either upper or lower limit position,

swing operation is performed in width 35° from the limit which the

stop position exceeded.

3) Swing

2) Louver position in heating operation

2) Air direction adjustment

• The position is automatically controlled according to the operation

• The set louver position is stored in memory by the microcomputer,

The angle of the louver is indicated as the louver closes fully is 0°.

1) Louver position in cooling operation

mode (COOL/HEAT).

and the louver returns to the stored position when the next operation

is performed. (Cooling/Heating memory position)

• Swing

When pressing

[SWING] button during

operation, the louver

starts swinging.

• The louver position can

be arbitrarily set up by

pressing [FIX] button.

33

FILE NO. SVM-07008