Caution, 2. indoor unit – Toshiba RAS-10SKV-A User Manual

Page 52

Advertising
background image

– 51 –

FILE NO. SVM-07008-1

10-2. Indoor Unit

10-2-1. Installation place

A place which provides the spaces around the
indoor unit as shown in the above diagram.

A place where there is no obstacle near the air inlet
and outlet.

A place that allows easy installation of the piping to
the outdoor unit.

A place which allows the front panel to be opened.

The indoor unit shall be installed as top of the
indoor unit comes to at least 2 m height.
Also it must be avoided to put anything on the top of
the indoor unit.

CAUTION

Direct sunlight to the indoor unit’s wireless
receiver should be avoided.

The microprocessor in the indoor unit should not
be too close to RF noise sources.
(For details, see the owner’s manual.)

<Remote controller>

A place where there are no obstacles such as a
curtain that may block the signal from the indoor
unit.

Do not install the remote control in a place exposed
to direct sunlight or close to a heating source, such
as a stove.

Keep the remote control at least 1 m apart from the
nearest TV set or stereo equipment. (This is
necessary to prevent image disturbances or noise
interference.)

The location of the remote control should be
determined as shown below.

Fig. 10-2-1

(Top view)

Indoor unit

Reception
range

Reception
range

Remote
control

Remote
control

(Side view)

10-2-2. Cutting a hole and mounting installation

plate

<Cutting a hole>

When installing the refrigerant pipes from the rear.

Fig. 10-2-2

1. After determining the pipe hole position on the

mounting plate (

A

), drill the pipe hole (

65 mm) at

a slight downward slant to the outdoor side.

NOTE:

When drilling a wall that contains a metal lath, wire
lath or metal plate, be sure to use a pipe hole brim
ring sold separately.

<Mounting the installation plate>

Fig. 10-2-3

Indoor unit

45

°

45

°

75

°

90 mm

66 mm

65 mm

42 mm

Pipe hole

62

85

82.5

170

Anchor bolt holes

Hook

Pipe hole

Indoor unit

Thread

Hook

Weight

Pipe hole

7

Mounting screw

Hook

1

Installation
plate

2 m or more fr

om floor

Advertising