Toshiba RAS-10SKV-A User Manual

Page 78

Advertising
background image

– 77 –

FILE NO. SVM-07008

1

Electrolytic capacitor

1. Turn OFF the power supply breaker.

(For raising pressure, smoothing)

2. Discharge all three capacitors completely.
3. Check that safety valve at the bottom of capacitor is not broken.
4. Check that vessel is not swollen or exploded.
5. Check that electrolytic liquid does not blow off.
6. Check that the normal charging characteristics are show in

continuity test by the tester.

C12, C13, C14

500

µ

F/400V

2

Converter module

1. Turn OFF the power supply breaker.

2. Discharge all three capacitors completely.

3 Check that the normal rectification characteristics are shown in continuity

test by the tester.

11-8-5. Checking Method for Each Part

Case that product is good

Pointer swings once, and
returns slowly. When
performing test once again
under another polarity, the
pointer should return.

No.

Part name

Checking procedure

Soldered

surface

Heat

sink

IGBT

side

C12 C13 C14

3

Outdoor temperature sensor

(TO), discharge temperature

sensor (TD), suction temperature

sensor (TS), outdoor heat

exchanger temperature sensor

(TE)

Disconnect the connector, and measure resistance value with the tester.

(Normal temperature)

TGa : Heat pump model only.
TO, TS, TE : Refer to the TA, TC characteristic table in Indoor

(Refer to Table 10-8-3, No.1).

Temperature

10°C

20°C

30°C

40°C

50°C

Sensor

TA, TC (k )

105

64

41

27

18

MCC-5009

Diode check

Tester rod

e

d

d

e

\

1

~

Resistance value

in good product

50k

or more

(0

in trouble)

\

2

~

\

1

~

\

2

~

Mark

2

1

1

2