– 83 –

12-3-1. Outdoor Unit

No.

Part name

Procedures

Remarks

1. Detachment
1) Stop operation of the air conditioner, and

turn off the main switch and breaker of the
air conditioner.

2) Remove the valve cover. (ST1T

4 x 10

s

1 pc)

After removing screw, remove the valve
cover pulling it downward.

3) Remove the wiring cover (ST1T

4 x 10

s

2

pcs.), and then remove the power cord,
connecting cable, and cord clamp
(ST2T

4 x 16

s

3 pcs.).

4) Remove the upper cabinet.

(ST1T

4 x 10

s

5 pcs.)

After removing screws, remove the
upper cabinet pulling it upward.

2. Attachment
1) Attach the upper cabinet.

(ST1T

4 x 10

s

5 pcs.)

Hook the rear side of the upper cabinet
to the claw of the rear cabinet, and then
place it on the front cabinet.

2) After connecting the power cord and

connecting cable, attach the cord clamp
and wiring cover.

Insert the upper part into the upper
cabinet, and insert the claw which has
been hooked to the lower part into the
square hole, and then fix it with screw.
(ST1T

4 x 10

s

1 pc.)

3) Attach the valve cover. (ST1T

4 x 10

s

1 pc.)

Insert the upper part to the upper
cabinet, set the hook claw of the valve
cover to square holes (at three
positions) of the main unit, and attach it
pushing upward.

1. Detachment
1) Perform work of item 1 of

1

.

2) Remove upper screw (ST1T

4 x 10

s

4 pcs.)

of the front cabinet, and lower screws
(ST1T

4 x 10

s

8 pcs.) of the front cabinet.

Both side of front cabinet envelop the

unit, so remove it by pulling sideward.

2. Attachment
1) Assemble front cabinet to the unit.

2) Attach the removed screws to the original

positions.

1

Common
procedure

2

Front cabinet

Upper cabinet

Wiring cover

Valve cover

Upper cabinet

Advertising
This manual is related to the following products: