24.6.3. C-001T

24.6.4. ZP-001T

6 V DC

15 mA

8 channels, open voltage: 3.3 V DC, short-circuit: under 1 mA,
removable terminal block (9 pins)

8 channels, open collector output, withstand voltage: 27 V DC,
control current: max. 50 mA, removable terminal block (9 pins)

–10 to +40°C

Panel: Aluminum, hair-line

35 (w) x 78 (h) x 91.5 (d) mm

62 g

Power Source

Current Consumption

Control Input

Control Output

Operating Temperature

Finish

Dimensions

Weight

+24 V DC, +6 V DC

38 mA (at +24 V DC), 18 mA (at +6 V DC)

1 line

DTMF signal

Loop-Start (or Ground-Start, selectable)

0 dB, 600

Ω, balanced, RJ-11 connector/removable terminal block (4 pins)

1 channel, no-voltage make contact, open voltage: 5 V DC,
short-circuit: 0.5 mA, removable terminal block (4 pins)

4 channels, open collector output (isolated), withstand voltage: 35 V DC,
control current: max. 50 mA, removable terminal block (4 pins)

–10 to +40°C

Panel: Aluminum, hair-line

35 (w) x 78 (h) x 91.5 (d) mm

153 g

Power Source

Current Consumption

Number of Lines

Type of Selectable Signal

Signaling System

TEL Line

Control Input

Control Output

Operating Temperature

Finish

Dimensions

Weight

Note: The design and specifications are subject to change without notice for improvement.

• Accessories

Removable terminal plug (9 pins) .................... 2
Machine screw M3 x 8 ..................................... 2

Note: The design and specifications are subject to change without notice for improvement.

• Accessories

Removable terminal plug (4 pins) .................... 3
Machine screw M3 x 8 ..................................... 2

Advertising